CAT730.5
- 2 to 416 gallons per minute [gpm], 120 to 25,000 gallons per hour [gph]
- Potable & high purity water applications
- 316 Stainless Steel, electropolished and passivated inside and out
- Removable flanged head for easy disassembly
- Patented dual action wiper mechanism for cleaning of the quartz sleeve
- Model S2400C has heads that can be removed & rotated
- Protective Coating for seawater & corrosive environments available
Unit Dimensions
(in.)
Shipping
Data (lb.)
Model GPM GPH
Inlet
and
Outlet
[NPT](1)
Replacement
Lamps
Power
Consumption
[Watts] (2)
LengthWidthHeight
Gross
Wt.
Net
Wt.
S14A
(3)
2 120 1/2" 05-1400-R 14 16-3/8
4-
5/16
8-3/16
11 7
S17A
(3)
3 180 3/4" 05-1098-R 18 19-3/8
4-
5/16
8-3/16
11 8
S23A
(3)
6 360 3/4" 05-1097-R 24 25-3/8
4-
5/16
8-3/16
14 14
S37C
(3)
12 720 1" 05-1343-R 44 39-3/8
5-
11/16
9-1/2 30 30
S50C
(3)
20 1,200 1-1/2" 05-1334-R 54 52-3/8
5-
11/16
9-1/2 36 36
S2400C
(4)
40 2,400 2" 05-1311-R 140 52-1/8 6-5/8 11-1/2
49 36
(1) All inlets and outlets are male pipe thread.
(2) Total power consumption including ballast loss (approximately).
(3) Units are manufactured in Type 316 Stainless Steel
(4) Unit is manufactured in Type 316 Stainless Steel and has dual removable heads.
• Maximum recommended operating pressure for all purifiers is 100 PSI.
• Pressure drop at maximum recommended flow rate is less than 5 PSI.
- 90 to 450 gallons per minute [gpm], 120,000 to millions of gallons per day [gpd]
- Manifolding multiple chambers achieves higher flow rates
- Clear wastewater, clear fresh and high purity water disinfection
- Modular, multi-lamp pressure vessel chamber
- Control panel includes display window, lamp operation indicator, elapsed time indicator;
dual removable flanged heads; dual drain fittings; multiple access ports and sight port
- Manual or automatic wiping mechanism and customized monitoring systems available.
Nominal
Capacities/GPM
Power **
Requirements
Unit Dimensions
(in.)
Model
Standard
Inlet /
Outlet *
Clear
Waste
Water
Clear
Fresh
Water
High
Purity
Water
Number
of
Lamps
120V 230V
Total
Watts
LengthWidthHeight
M50
2"
NPT
70 90 100 4
4
AMPS
2.1
AMPS
480 100 16 14
M90
3" 150#
Flange
115 150 190 7
6.5
AMPS
3.4
AMPS
780 100 16 16
M150
4" 150#
Flange
200 270 325 12
9
AMPS
4.7
AMPS
1080 100 18 18
M250
4" 150#
Flange
335 450 560 19
14
AMPS
7.3
AMPS
1680 102 21 26